7
MODEL FOR MOTORS INPUT (50-60 Hz) OUTPUT HEAT LOSS
NUMBER RATED INPUT CURRENT POWER CURRENT (WATTS)
HP kW PHASE (AMPS) (kVA) (AMPS) (NOTE 2)
400/480 Vac
0 - 400/460 Vac
(NOTE 3)
174459 0.5 0.37 3 1.6/1.4 1.1 1.3/1.1 26
174460 1 0.75 3 2.9/2.5 2.1 2.4/2.1 40
174461 1.5 1.1 3 4.0/3.6 3.0 3.4/3.0 56
174462 2 1.5 3 4.6/4.0 3.3 3.9/3.4 67
174463 3 2.2 3 6.2/5.4 4.5 5.5/4.8 100
174447 5 3.7 3 9.8/8.6 7.1 8.7/7.6 168
174440 7.5 5.5 3 14.2/12.4 10.3 12.6/11.0 254
174441 10 7.5 3 18.1/15.8 13.1 16.1/14.0 310
174431 15 11 3 27/24 20.0 24/21 390
174432 20 15 3 35/31 25.8 31/27 530
174433 25 18.5 3 44/38 31.6 39/34 648
174500 30 22 3 53/45 37.4 46/40 770
480/590 Vac
0 - 460/575 Vac
(NOTE 4)
174464 1 0.75 3 2.2/2.0 1.9/2.0 1.9/1.7 40
174491 2 1.5 3 4.0/3.5 3.3/3.6 3.4/3.0 67
174497 3 2.2 3 4.7/4.7 3.9/4.8 4.2/4.2 100
174448 5 3.7 3 7.4/7.4 6.1/7.5 6.6/6.6 168
174442 7.5 5.5 3 11.2/11.2 9.3/11.4 9.9/9.9 254
174443 10 7.5 3 13.7/13.7 11.4/14.0 12.2/12.2 310
174434 15 11 3 22/22 18.3/22.5 19.0/19.0 390
174435 20 15 3 27/27 22.4/27.6 24/24 530
174436 25 18.5 3 31/31 25.8/31.7 27/27 648
NOTE 2: Values are worst-case (not typical) for 6 kHz carrier frequency at full speed and full load.
NOTE 3: The higher current ratings are for 400 Vac input and the lower current ratings are for 480
Vac input.
NOTE 4: The higher current ratings for for 480 Vac input and the lower current ratings are for 590
Vac input.