Manual

6
MODEL FOR MOTORS INPUT (50-60 Hz) OUTPUT HEAT LOSS
NUMBER RATED INPUT CURRENT POWER CURRENT (WATTS)
HP kW PHASE (AMPS) (NOTE 1) (kVA) (AMPS) (NOTE 2)
120/208/240 VAC 0 - 230/200/230 VAC
174492 1 0.75 1 16.6/9.6/8.3 2.0 4.2/4.8/4.2 48
174445 1.5 1.1 1 24/13.9/12.0 2.9 6.0/6.9/6.0 73
208/240 Vac 0 - 200/230 Vac
174452 0.25 0.20 1 3.6/3.2 0.76 1.6/1.4 19
174452 0.25 0.20 3 1.9/1.7 0.71 1.6/1.4 19
174453 0.5 0.37 1 5.4/4.7 1.2 2.5/2.2 26
174453 0.5 0.37 3 3.1/2.7 1.1 2.5/2.2 26
174454 1 0.75 1 10.6/9.2 2.2 4.8/4.2 49
174454 1 .075 3 5.8/5.1 2.1 4.8/4.2 49
174493 1.5 1.1 1 13.9/12.0 2.9 6.9/6.0 82
174493 1.5 1.1 3 8.0/6.9 2.9 6.9/6.0 82
174494 2 1.5 1 14.8/12.9 3.1 7.8/6.8 86
174494 2 1.5 3 9.1/7.9 3.2 7.8/6.8 86
174495 3 2.2 1 19.7/17.1 4.1 11.0/9.6 130
174495 3 2.2 3 12.4/10.8 4.4 11.0/9.6 130
174444 5 3.7 1 29/26 6.1 17.5/15.2 212
174444 5 3.7 3 19.6/17.1 7.1 17.5/15.2 212
208/240 Vac 0 - 200/230 Vac
174455 1 0.75 3 5.8/5.1 2.1 4.8/4.2 41
174456 1.5 1.1 3 8.0/6.9 2.9 6.9/6.0 69
174457 2 1.5 3 9.1/7.9 3.3 7.8/6.8 78
174458 3 2.2 3 12.4/10.8 4.5 11.0/9.6 117
174446 5 3.7 3 19.6/17.1 7.1 17.5/15.2 187
174438 7.5 5.5 3 28/25 10.3 25/22 286
174439 10 7.5 3 34/32 13.1 30/28 379
174429 15 11 3 54/48 20.0 48/42 476
174430 20 15 3 65/61 25.4 58/54 648
NOTE 1: The higher current ratings are for 208 Vac input and the lower current ratings are for 240
Vac input.
NOTE 2: Values are worst-case (not typical) for 6 kHz carrier frequency at full speed and full load.
5.0 SM-Plus
RATINGS