Instruction Manual
1
SPEEDMASTER™ OPERATION MANUAL
Specifications
Max.
Armature HP Range HP Range
Current with 115 VAC with 230 VAC
Model (Amps DC) Applied Applied Style
174102 10.0 1/8–1 1/4–2 NEMA 4X
174103 10.0 1/8–1 1/4–2 NEMA 4X
174107 10.0 1/8–1 1/4–2 NEMA 4X
AC Line Voltage 115 VAC or 230 VAC ±10%, 50/60 Hz, single phase
Armature Voltage (115 VAC Input) 0–90 VDC
Armature Voltage (230 VAC Input) 0–180 VDC
Form Factor 1.37 at base speed
Field Voltage (115 VAC Input) 50 VDC (F1 to L1); 100 VDC (F1 to F2)
Field Voltage (230 VAC Input) 100 VDC (F1 to L1); 200 VDC (F1 to F2)
Max. Field Current 1 ADC
Accel. Time Range:
for 0–90 VDC Armature Voltage 1 – 15 seconds
for 0–180 VDC Armature Voltage 1 – 15 seconds
**Analog Input Voltage Range (signal must be isolated; S1 to S2):
for 0–90 VDC Armature Voltage 0 – 1.4 VDC
for 0–180 VDC Armature Voltage 0 – 2.8 VDC
Decel. Time Range:
for 0-90 VDC Armature Voltage 1 – 15 seconds
for 0–180 VDC Armature Voltage 1 – 15 seconds
Current Limit Range:
for 0–90 VDC Armature Voltage 0 – 14 A
for 0–180 VDC Armature Voltage 0 – 13.5 A
Input Impedance (S1 to S2) 3M ohms
Load Regulation 1% base speed or better
Vibration 1G max (0–50 Hz)
Ambient Temp. Range (cased drive) 10°C–40°C
**Does not Apply to 174103