Product Manual

-62-
Relubrication Intervals Chart
For Motors Having Grease Fittings
Hours of Service HP Range Suggested
Per Year Relube Interval
5000 1/18 to 7
1
/
2
5 years
10 to 40 3 years
50 to 100 1 year
Continuous Normal to 7
1
/
2
2 years
Applications 10 to 40 1 year
50 to 100 9 months
Seasonal Service - All 1 year
Motor is idle for (beginning of
6 months or more season)
Continuous high 1/8 to 40 6 months
ambient, high 50 to 150 3 months
vibrations, or where
shaft end is hot
Caution: Keep grease clean. Lubricate motors at a standstill. Do not mix petroleum
grease and silicone grease in motor bearings.