Product Manual

-53-
Position G: Electrical Type (Single Phase Only): [cont’d]
Commonly used voltage codes:
60 Hz 50 Hz
61 = 230/460 V 51 = 220/380 V
62 = 200/400 52 = 240/415
63 = 208 53 = 230/400
64 = 460 54 = 200/400
65 = 575 55 = 380
66 = 230 56 = 400
67 = 440 57 = 415
68 = 380 58 = 440
69 = 480 59 = 220/440
6003 = 220/380 5001 = 190/380
6004 = 220/440 5007 = 346
6020 = 2300 5012 = 550
6021 = 4000 5014 = 380-415
6024 = 2300/4000
6026 = 208-230/460
6027 = 115/230
6028 = 115/208-230
6029 = 208-220/440
Reduced Voltage Start Capability:
P = Part winding start (PWS)
Y = Wye-delta start (YDS)
PY = PWS and YDS
Position H: Options/Modifications:
If a motor has more than one Option / Modification, the
symbols
will appear in alphabetical order.
AP1 CE Compliant Motor
AP5 Fire Pump certified
AP7 Farm Duty, High Torque
AP8 Farm Duty, Extra High Torque
AP9 Grain Stirring
AP10 PSC Variable Speed
AP11 PSC Variable Speed, expanded speed range
AP13 UL Listed Class 1 Groups C & D and
Class 2 Groups F & G, thermostats
AP14 UL Listed Class 1 Groups C & D and Class 2
Groups F & G, auto reset thermal protector
AP15 UL Listed Class 1 Group D and
Class 2 Groups F & G, thermostats
AP21 Non NAFTA Qualified
AP23 Non NAFTA Qualified
AP25 Non NAFTA Qualified
B F-2 Mount
C_ Ceiling Mount - NEMA position follows “C”; 1-2
E3 Class H Insulation
E5 Class H Insulation & High Temperature Grease
F Fungus Proofing (Tropicalization)
H4 Leads exit motor at 12 o’clock position
HS Precision Dynamic Balance
HT1 Space Heater, 120V
HT2 Space Heater, 240 V
K Omit Terminal Box
L_ Additional Lead Length - “L” followed by
additional length in inches
MB3 Insulated bearings, both ends
MB6 Double sealed bearings, both ends
MK_ Brake installed on motor
Q10 CTAC® Inverter Duty Motor with provision
for mounting feedback device
Q15 CTAC Inverter Duty Motor with factory
installed Dynapar 625 1024 ppr encoder
Position H: Options/Modifications: (cont’d)
Q15_ CTAC Inverter Duty Motor with factory
installed encoder - letter following “Q15”
represents brand and ppr rating of encoder,
A through S.
Q20 CTAC Inverter Duty motor without provision
for mounting feedback device
Q40 CTAC Inverter Duty Motor without provision
for mounting feedback device
QS10 Crop dryer (single phase, auto reset)
QS11 Crop dryer (single phase, thermostats)
QS12 Crop dryer (three phase, thermostats)
RB Roller bearing on drive end
T1 Thermostats, Class F, 3 in series
T5 Thermostats (2) Class F
TD1,2 RTD - Winding, 100 Ω platinum
TD4 RTD - Winding, 10 Ω copper
TD6 RTD - Winding, 120 Ω nickel
TP1 Overload protection, manual reset
TP2 Overload protection, auto reset
TX1 Thermistors, 3 in series
W_ Wall Mount - W followed by NEMA position
number, 1-8
X_ Paint color deviation