User's Manual
4
4‐2‐2TransmitterLEDindicator
Thereisa3‐stagepowerindicatingfunctionwithLEDdisplay.
1."Greencolor":Sufficientpowertooperatetransmitter.
2."Yellowcolor":Powerisdepleting.Operationmustbestopped
immediately(forexample:downtheloadstoground)toreplace
batteries.
3."Redcolor":Insufficientpower.Transmitterwillsend
outanemergency
stopsignaltothereceiverduetoinsufficientpower.Operatorshould
avoidthissituationinordertomaintainthesafetyofoperation
.
5. RECEIVERPOWERSELECTION
5‐1Receiverpowertransformervoltageselection
F21‐E2receiverprovideswith5kindsofTransformer(24V/48VAC、48/110
VAC、48/220VAC、110V/220VAC、220V/380VAC)thatallowsuserto
choosebasedonthepowerinputonsiteandthedesignatedvolta gewillbe
setwhenthereceiverismadein
factory.
5‐2Changepowersupplyvoltage
1.Disconnectthepowerofreceiver.
2.Removetheconnectorplugofthetransformerfromitsoriginalposition.
3.Inserttheconnectorplugintothenewposition.
4.Completetheprocedure.
Transformer
Jumper
24/48
VAC
48/110
VAC
48/220
VAC
110/220
VAC
220/380
VAC
LOposition 24VAC 48VAC 48VAC 110VAC 220VAC
HIposition 48VAC 110VAC 220VAC 220VAC 380VAC
Note:Usersareallowedtoselectthedifferentpowersourceaccordingtothe
respectiverequirement.However,thetransformermustbechanged.
Pleasecheckwithyourlocaldistributorforreplacementofthe
transformerifnecessary.
www.telecrane.com.tw