Installation Guide

DMX512 to SPI decoder and RF controller with digital display.
Compatible with 34 kinds digital IC RGB or RGBW LED strip, IC type and R/G/B order can be set.
Compatible ICs: TM1803, TM1804, TM1809, TM1812, UCS1903, UCS1909, UCS1912, UCS2903, UCS2909,
UCS2912, WS2811,WS2812, TM1829, TLS3001, TLS3002, GW6205, MBI6120, TM1814B, SK6812, UCS8904B,
LPD6803, LPD1101, D705, UCS6909, UCS6912, LPD8803, LPD8806, WS2801, WS2803, P9813, SK9822, TM1914A,
GS8206,GS8208.
DMX decode mode, stand-alone mode and RF mode selectable.
Standard DMX512 compliant interface, set DMX decode start address by buttons.
Under stand-alone mode, change mode, speed or brightness by bottons.
Under RF mode, match with RF 2.4G RGB/RGBW remote control.
32 kinds dynamic mode, include horse-race, chase, flow, trail or gradual change style.
Control dots
170 pixels (RGB 510 CH)
Max 900pixels
Dynamic mode
32
Input signal
DMX512 + RF 2.4GHz
Output signal
SPI(TTL) x 3
Input voltage
5-24VDC
Power consumption
1W
User Manual Ver 1.0.9
Technical Parameters
Input and Output
Warranty and Protection
5 years
Protection Reverse Polarity
Warranty
Operation temperature
Case temperature (Max.)
Environment
IP20
IP rating
Ta: -30
O
C ~ +55
O
C
T c:
+65
O
C
Model No.: DSA
Features
Page 1
Mechanical Structures and Installations
Compatible with 34 kinds IC/Numeric display/Stand-alone function/Wireless remote control
Power input -
Power input +
DMX512-SPI Decoder and RF Controller
DATA1 signal output
CLK1 signal output
DSA DMX512-SPI Decoder and RF Controller
LVD
Safety and EMC
EMC standard (EMC)
Certification
CE,EMC,LVD
EN 61347-1:2015
EN 61347-2-11:2015
Safety standard(LVD)
EN55032:2015,
EN61000-3-2:2014,
EN61000-3-2:2013,
EN55024 :2010/A1:2015
Wiring diagram
V+
GND
CLK2 signal output
DATA2 signal output
DMX input/output +
DMX input/output -
Installation rack
GND
AC100-240V
Power Supply
5-24VDC
Constant Voltage
165.00 mm
70.00 mm
37.00 mm
D+
D-
D+
D-
GN D
DM X in/ou t
1 2
3
12
3
M
1 23 4 5 6 7 8
DM X in/ou t
1 2
3
12
3
1 23 4 5 6 7 8
DM X in/ou t
Setting key
Digital display
DMX input/output +
DMX input/output -
RJ45 DMX signal
RJ45 DMX signal
XLR3 male DMX signal
XLR3 female DMX signal
CLK3 signal output
DATA3 signal output
D+
D-
D+
D-
GND
DMX i n/out
1 2
3
12
3
M
1 2 34 5 6 7 8
DMX i n/out
1 2
3
12
3
1 2 34 5 6 7 8
DMX i n/out
DMX
Master
V+
V-
DA
RGB LED pixel strip
Note:
If the SPI LED pixel strip is single-wire control, the DATA and CLK output is same, we can connect up to 6 LED strips.
If the SPI LED pixel strip is two-wire control, we can connect up to 3 LED strips.

Summary of content (2 pages)