User Manual

Table Of Contents
Page 43 of 129 54A0028-6 042019 © LeddarTech Inc.
Table 12: Measurement rate for LeddarVu8
Accumulation
Oversampling
Measurement Rate (Hz)
LeddarVu
16°
LeddarVu
47.5°
LeddarVu
98.5°
1024
8
0.1356
0.2713
0.5425
512
8
0.2713
0.5425
1.0851
256
8
0.5425
1.0851
2.1701
128
8
1.0851
2.1701
4.3403
64
8
2.1701
4.3403
8.6806
32
8
4.3403
8.6806
17.3611
1024
4
0.2713
0.5425
1.0851
512
4
0.5425
1.0851
2.1701
256
4
1.0851
2.1701
4.3403
128
4
2.1701
4.3403
8.6806
64
4
4.3403
8.6806
17.3611
32
4
8.6806
17.3611
34.7222