User Manual

100 P/N 54A0028-2 012017© 2017 LeddarTech Inc. Printed in Canada. All rights reserved.
Flag
The Flag column displays a number that represents a detection type.
Table 68: Flag value description
Bit position
Bit 0
Bit 1
0
Invalid measurement
Valid measurement
1
Reserved
Reserved
2
Reserved
Reserved
3
Normal measurement
Received signal is above the saturation level.
Measurements are valid (VALID is set) but
have a lower accuracy and precision.
Consider decreasing the light source intensity.
4
Reserved
Reserved
5
Reserved
Reserved
6
Reserved
Reserved
7
Reserved
Reserved
The Flag parameter provisions for 8 bits encoded as a bit field. Three bits are
currently used. The following table presents the implemented decimal values of the
status bit field.
Table 69: Status value description
Status value
(decimal)
Status value
(binary)
Description
1
00000001
Normal measurement (valid)
9
00001001
Saturated signal (valid)