Leddar One Manual

Leddar™One Sensing Module 37
4.4.6. Data Logging
The data logging function is used to output data to a text file. This file can be
imported in a software application, such as Microsoft Excel, for offline analysis.
The duration of the logging is indicated in the status bar.
Each line of the generated text file contains the information related to a single
detection.
Table 12: Data Log Field Description
Time (msec)
Segment [Always 1]
Amplitude [0 128]
Distance (m)
Status
422530
1
127.42
6.95
1
The time of the detection is 422530 milliseconds from the time the
sensor was started.
The location of the detection is segment 1.
The amplitude of the detection is 127.42, which is very high (big, near,
or reflective object). Note: Typically the range of amplitude is between
0 and 128 but if the signal is saturated, the range can exceed 128.
The distance of the detection is 6.95meters.
The status is always 1.
To use the data logging function:
1. On the Settings menu, click Start Data Logging
Figure 23: Setting Menu
2. In the Directory dialog box, click the browse button to select the path
where you want to save the log and click OK.