Instruction Manual

page6/9/2022 7
Sensors in Rows
www.ledalite.com
!
ATTENTION: Install in accordance with national and local building and electrical codes.
Single Sensor Controlling Whole Row
1. Purple & brown (or purple & grey/pink) control wires MUST
be connected between fixtures.
Note:
A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
Multiple Sensors Controlling Separate Zones in a Row
2. Purple & brown (or purple & grey/pink) control wires MUST NOT
be connected between zones.
Notes:
A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).
Sensors too close
for correct operation.
Sensors at minimum
required distance
for correct operation.
Sensors at a maximum
distance of 40ft apart.
40ft Max.
Integral Sensor
Integral Sensor
Sensor Spacing
For correct operation, sensors should be placed a minimum distance of 8ft apart.
Wireless sensors should be placed no further than 40ft apart for good wireless signal connection.
Important Consideration When Using Sensors in a Row
For fixtures with wireless sensors (CS, SB or RA options):
DO NOT
connect fixture purple & brown (or purple & grey/pink) control wires to an external dimming switch.
Fixture mains wiring should not be connected to a circuit with an external on/off switch.
For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will
break the continuous lens into discrete sections. Alternatively, remote sensor may be used, note the same
wiring rules will apply.
Bottom view of fixtures
Integral Sensor
8ft4ft
1
Bottom view of fixtures
Alternate
Remote Sensor
Integral Sensor
8ft
4ft
2
Bottom view of fixtures
Integral Sensor
Zone 2Zone 1
Alternate
Remote Sensor
8ft4ft
Bottom view of fixtures
Integral Sensor
Integral Sensor
Alternate
Remote Sensor
Integral Sensor
8ft
4ft
Bottom view of fixtures
Sensor
Zone 2Zone 1
Alternate
Remote Sensor
Alternate
Remote Sensor