Manual
Chapter Eleven: Easy example
Sample 1:
Take guardrail tube as example, IC is DM134 with OE.
A. Start “LED Build software”, click menu “setting”—“setting sculpt” to enter Lighting Sculpt
Interface.
B. In Lighting Sculpt window, set lighting sculpt.
1.Click “File”—“New”
Set width and height, click “OK”.
2. Select “four line with a slave”, line limit pixels is 400
3. Drag the mouse from top left to bottom right. As shown in following picture, four ports have each
400 pixels.