User's Manual

SSM
LECTROSONICS, INC.
10
Setup Screens
DOWN Button Menu
Hold the DOWN button while powering up the unit. Then press the AUDIO button repeatedly to scroll through the
following settings. Use the UP and DOWN arrows to select the available options under each setting.
rc - remote control operation; selections: on, oFF
PbAc - power-back-on after power loss; selections: 0 (stay turned off), 1 (turn back on)
bL - back light duration; selections: 5 (minutes), 30 (seconds), on (always on)
UP Button Menu
Hold the UP button while powering up the unit. Then press the AUDIO button repeatedly to scroll through and se-
lect the following settings (bulleted). Use the UP and DOWN arrows to select the available options under each setting.
CP - compatibility mode; press the UP and DOWN arrows to select one of the following:
CP 400 400 Series (Digital Hybrid) mode
CP 3 Mode 3 (contact the factory for details)
CP 200 200 Series mode; receivers such as UCR200/201/205D/210/211
CP 100 100 Series mode; UCR100 receiver
CP 7 Mode 7 (contact the factory for details)
CP 6 Mode 6 (contact the factory for details)
CP IFb IFB Series mode; IFBR1/1a receivers
Pr - RF power output; selections: 25, 50
In - Input configuration; press the UP and DOWN arrows to select one of the following:
In dYn no bias, lo-Z; use for dynamic microphones
In 152 4v bias, lo-Z; same as otH; listed for easy selection on Lectrosonics 152 and similiar mics
In SEN 4v bias, lo-Z; same as otH; listed for easy selection on Sennheiser MKE 2 and similiar mics
In SEt Press the AUDIO button for manual setup of input for explicit control over bias voltage, input
resistance and audio polarity. Press the AUDIO button to select the following
parameters, then use the UP and DOWN arrows for each item to set the values.
bIAS - bias voltage on the input; selections 0, 2 or 4
rES - input impedance; selections: 0 (300 ohms), Lo (approx. 4 k ohms) or HI (approx. 100 k ohms)
AP - audio polarity (aka “phase”); selections: P for positive, n for negative (reversed)
NOTE: When you press AUDIO after setting the polarity, the screen will leave this submenu and return
to the In menu. To return to this submenu, press AUDIO repeatedly and scroll through the list again.
In otH 4v bias, lo-Z; same as CoS but audio phase is not reversed; for various mics
In L In no bias, hi-Z; use for line level input (
See Line Input Wiring and Use on page 11)
In dPA 4v bias, mid-Z; use for DPA lavaliere and similar mics
In b6 2v bias, lo-Z; use for Countryman B6 and similar mics
In CoS 4v bias, lo-Z; phase reversed; use for Sanken COS-11, M152 and similar mics
StP - Frequency tuning step size in kHz; selections: 25 kHz or 100 kHz