Instruction Manual
Digital Hybrid Wireless Belt-Pack Transmitters
Rio Rancho, NM
13
Selecting Step Size
This menu item allows frequencies to be selected in
either 100 kHz or 25 kHz increments.
Rolloff
Compat
StepSiz
Phase
StepSiz
100 kHz
25 kHz
StepSiz
100 kHz
25 kHz
If the desired frequency ends in .025, .050 or .075 MHz,
the 25 kHz step size must be selected.
Normally, the receiver is used to find a clear operat-
ing frequency. All Lectrosonics Digital Hybrid Wireless
®
receivers provide a scanning function to quickly and
easily find prospective frequencies with little or no RF
interference. In other cases, a frequency may be speci-
fied by officials at a large event such as the Olympics
or a major league ball game. Once the frequency is
determined, set the transmitter to match the associated
receiver.
Selecting Audio Polarity (Phase)
Audio polarity can be inverted at the transmitter so the
audio can be mixed with other microphones without
comb filtering. The polarity can also be inverted at the
receiver outputs.
Rolloff
Compat
StepSiz
Phase
Phase
Pos.
Neg.
Setting Transmitter Output Power
The output power can be set to 25 mW, 50 mW or
100 mW.
Compat
StepSiz
Phase
TxPower
TxPower
25 mW
50 mW
100 mW
Setting Scene and Take Number
Use UP and DOWN arrows to advance Scene and Take
and MENU/SEL to toggle. Press the BACK button to
return to menu.
Sc&Take
Scene 1
Take 5
TxPower
Sc&Take
Take s
Naming
Choosing Takes for Replay
Use UP and DOWN arrows to toggle and MENU/SEL to
play back.
TxPower
Sc&Take
Take s
Naming
Take s
S01 T001
S01 T002
S02 T001
S03 T001
Recorded File Naming
Choose to name the recorded files by the sequence
number or by the clock time.
Naming
Seq #
Clock
TxPower
Naming
SD Info
Default
SD Info
Information regarding the microSDHC memory card
including space remaining on card.
TxPower
Naming
SD Info
Default
[SMWB ]
Max Rec
E.........................F
0/ 14G
Fuel gauge
Storage used
Storage capacity
Available recording
time (H : M : S)
Restoring Default Settings
This is used to restore the factory settings.
TxPower
Naming
SD Info
Default
Default
settings
No
Ye s