User's Manual
LT
LECTROSONICS, INC.
14
Enabling Remote Control
Transmitter settings can be configured using special 
tones generated by a smartphone using a remote 
control application such as Lectro RM (available on the 
AppStore or Google Play). Enable this feature on the 
transmitter with the following menu items.
BatType
Remote
TxPow er
Default
Remote
Enable
Ignore
The following settings can be configured:
•  Tx Input Gain
• Sleep/Unsleep
• Lock/Unlock
•  Tx power output
• Frequency
Setting Transmitter Output Power
The output power can be set to 50 mW or 100 mW.
BatType
Remote
TxPow er
Default
TxPower
50 mW
100 mW
Restoring Default Settings
This is used to restore the factory settings.
BatType
Remote
TxPow er
Default
Default
settings
No
Ye s
IR Sync Operation
A Lectrosonics receiver with IR Sync capability can 
transfer the settings for Frequency, Step Size and Com-
patibility mode to the transmitter via the IR ports. The 
transfer is triggered by a switch in the receiver. When 
the settings are successfully transferred, a confirmation 
will appear on the transmitter LCD.
IR Sync
 OK
If a mismatch exists and the transfer cannot be com-
pleted, an error message will appear on the transmitter 
LCD indicating what the problem is.
IR Sync
 BLOCK
Mismatch
IR Sync
 COMPAT
Mismatch
BLOCK Mismatch indicates that the transmitter and 
receiver are on different frequency blocks and the 
frequency cannot be set to match. COMPAT Mismatch 
will appear when the compatibility mode in the receiver 
is not available in the transmitters; for example, when 
you are trying to sync a US model to work an export 
model.