User's Manual
Compact Portable Receiver
Rio Rancho, NM
11
Menu Item Descriptions
Smart Tune
An automatic scanning function that identiļ¬es a usable 
frequency and sets the receiver on it. After the scan is 
complete, an option will appear to transfer the settings 
to an IR enabled transmitter. The receiver will remain 
set on the newly discovered frequency whether or not 
the IR transfer option was used.
Frequency
Allows manual selection of the operating frequency.
IR Sync
Transfers frequency, step size and compatibility mode 
from the receiver to the associated transmitter.
RF Scan
Launches the manual spectrum scanning function.
Clear Scan
Erases scan results from memory.
Audio Level
Adjusts the audio output level of the receiver.
Step Size
Selects 100 kHz or 25 kHz steps in the frequency 
adjustments.
Group
Convenient access to predetermined groups of fre-
quencies. Each group, U, V, W and X can hold up to 32 
channels each.
Tx Battery
Selects the type of battery being used in the associ-
ated transmitter for accurate battery status monitoring. 
The transmitter battery timer option is included in this 
setup screen.
Rx Battery
Selects the type of battery being used in the receiver 
for accurate battery status monitoring.
Compat. Mode
Selects the compatibility mode for use with a wide vari-
ety of Lectrosonics and other brands of transmitters.
Polarity
Selects the audio polarity (phase) of the receiver out-
put to match other components and different micro-
phone capsule wiring.
Smart NR
Selects the level of noise reduction applied to the 
audio signal.
Sq. Bypass
Defeats the audio muting (squelch) to allow audio 
output from the receiver regardless of the presence 
or lack of a matching transmitter. Used for diagnostic 
purposes.
Backlight
Selects the length of time the backlight on the LCD 
remains turned on.
LCD Mode
Selects the text/background appearance of the LCD.
Default
Returns all settings to the factory defaults:
  Menu Item  Setting
Frequency 8,0 (middle of lowest frequency 
block)
Audio Level 0 dBu
Compat.Mode NA Dig. Hybrid
Smart NR Normal
Polarity Normal (not inverted)
Step Size 100 kHz
LCD Mode White characters on dark 
background
Tx Battery AA alkaline
Rx Battery Alkaline
Battery Timer Reset to 0
Sq. Bypass Normal (squelch operational)
Tone output Off (in Audio Level setup 
screen)
Backlight Always on
Keypad status Not locked