Owner manual
DNT Digital Processor
LECTROSONICS, INC.
10
Mandatory Settings
Dante Controller Software - Network 
Settings
Connect the processor to the computer with the Dante 
Primary port either directly or through a gigabit switch. 
Confirm that the 1G and LINK/ACT LEDs next to the 
Dante port are flickering.
Launch the Dante Controller software. A brief splash 
screen appears, followed by the Network View/Rout-
ing screen. The serial number of the connected pro-
cessor will appear in the bars labeled Receivers and 
Transmitters.
Processor name and 
serial number appear in 
the blue bars
Double click on either blue 
bar to open the Device View 
dialogue box
Double click on the processor name/serial number to 
open the Device View dialog box. Under the Network 
Config tab, select Switched.
Select 
Network 
Config
Select 
Switched
Dante Primary Port
Select the Device Config tab, then set the sample 
rate to 48k. The sample rate MUST be 48k so the DSP 
(filters, etc.) will operate as they should.
Device Config Tab
Select 48k Sample Rate
Latency can be adjusted under the same tab. The 
setting depends upon the number of switches in the 
network.
The other tabs in the Device View dialog box are used 
to rename channels and check the status of several 
parameters.
Consult the Help menu for details and explanations of 
Dante Controller software.
NOTE: Once everything is set up and audio is 
flowing to and from the network, a second gigabit 
switch and network can be added and the mode 
can be changed to Redundant.