User Manual
DBa
LECTROSONICS, INC.
8
Powering On in Operating Mode
Press and hold the Power Button for several seconds
until a counter on the LCD progresses from 1 through 3.
Hold
for
Rf On
...3
DBa
V0.03
470.100
-40
-20
+0
DBa
When you release the button, the unit will be operation-
al with the RF output turned on and the Main Window
displayed.
Powering On in Standby Mode
A brief press of the Power Button , releasing it before
the counter has reached 3, will turn the unit on with the
RF output turned off. In this Standby Mode the menus
can be browsed to make settings and adjustments with-
out the risk of interfering with other wireless systems
nearby.
Hold
for
Rf On
...1
Release Power
Button before
the counter
reaches 3 to
enter standby
mode
470.100
-40
-20
+0
DBa
RF indicator blinks
After settings and adjustments are made, press the
power button again to turn the unit off.
NOTE: Also see the section entitled Power Menu
for the AutoOn feature.
Powering Off
Powering
O . . .
1
From any screen, power can be
turned off by selecting Pwr Off in the
power menu, holding the Power
Button
in and waiting for the
countdown, or with the program-
mable switch (if it is configured for
this function).
If the power button is released, or the top panel switch
is turned back on again before the countdown is com-
pleted, the unit will remain turned on and the LCD will
return to the same screen or menu that was displayed
previously.
NOTE: If the programmable switch is in the OFF
position, power can still be turned on with the
power button. If the programmable switch is then
turned on, a brief message will appear on the LCD.
Power Menu Options
Entering the Power Menu
Press the power button from any menu or screen
and a menu with appear with several options. Use the
and arrow buttons to select the menu item. Then
press MENU/SEL to execute the item or enter a setup
screen. See opposite page for details.
• Resume - returns to the previous mode and screen
• Rf On? - enters a screen to enable the operating or
standby modes
• AutoOn? - allows the unit to automatically turn
back on after a power failure or when fresh batter-
ies are installed (works in the operating mode only)
• Pwr Off - turns the unit off irrevocably
Resume
Rf On?
AutoOn?
Pwr Off
Resume and Pwr Off
will execute
the command
immediately
Resume
Rf On?
AutoOn?
Pwr Off
Resume and Pwr Off will execute the command imme-
diately. The other menu items will open a screen asking
for a value to be selected.
Rf On?: The RF output of the transmitter can be turned
off and on.
Resume
Rf On?
AutoOn?
Pwr Off
Rf On?
Ye s
No
The screens that
prompt for a selection to be made are straightforward as
in this example. Use the UP and DOWN arrows to
highlight the desired selection an press MENU/SEL or
BACK to confirm it.
Resume
Rf On?
AutoOn?
Pwr Off
AutoOn?
No
Ye s