User manual
Operator's Manual 
919586 RevA 
143 
BRIEF HS RISE & FALL TEST DESCRIPTIONS  
  With HS Rise & Fall selected in the Category field, the following Measure values are available: 
TR-DATA, TF-DATA, TR-CLK, and TF-CLK. 
Note: As mentioned previously in this section, when this category is selected, DATA/CLK-VOD1, 
DATA/CLK-VOD0, and Find Levels controls are also shown. Provide values for the additional fields or 
use the Find Levels button as desired. 
Name 
Purpose 
TR-DATA 
To verify that the 20%-80% Rise Time (tR) of the DUT Data & Clock Lanes HS transmitter is within 
the conformance limits. 
TR-CLK 
TF-DATA 
To verify that the 80%-20% Fall Time (tF) of the DUT Data & Clock Lanes HS transmitter is within 
the conformance limits. 
TF-CLK 
Official MIPI D-PHY Test Algorithms 
Specific test information is maintained by the MIPI Alliance and can be found at www.mipi.org. 
Note: Registration with the Alliance is required to access the document. 
EYE DIAGRAM CONTROL AREA 
Note: Some of the controls on this dialog are enabled/disabled based on Mode, Probing, and Input Selection 
control choices. 
The Eye Diagram Control Area of the MIPI D-PHY dialog contains Show Eye, Eye Source, Bit Rate, and Find Bit 
Rate controls. As controls are used, MIPI M-PHY processes the information and responds in real time. 