User manual
Operator's Manual 
919586 RevA 
137 
Category and Measure Combinations for LP Dphy1 - X Dialogs 
BRIEF LP LEVELS TEST DESCRIPTIONS 
  With LP Levels selected in the Category field, the following Measure values are available: 
VOH-Dp, VOH-Dn, VOH-CLKp, VOH-CLKn, VOL-Dp, VOL-Dn, VOL-CLKp, and VOL-CLKn. 
Name 
Purpose 
VOH-Dp 
To verify that the Thevenin Output High Level Voltage (VOH) of the DUT’s Data & Clock Lanes 
LP transmitter is within the conformance limits. 
VOH-Dn 
VOH-CLKp 
VOH-CLKn 
VOL-Dp 
To verify that the Thevenin Output Low Level Voltage (VOL) of the DUT’s Data & Clock Lanes LP 
transmitter is within the conformance limits. 
VOL-Dn 
VOL-CLKp 
VOL-CLKn 
BRIEF LP RISE & FALL TEST DESCRIPTIONS 
  With LP Rise & Fall selected in the Category field, the following Measure values are available: 
TRLP-Dp, TRLP-Dn, TRLP-CLKp, TRLP-CLKn, TFLP-Dp, TFLP-Dn, TFLP-CLKp, and TFLP-CLKn. 
Note: As mentioned previously in this section, when this category is selected, Dn-VOH, Dn-VOL, and 
Find Levels controls are also shown. Provide values for the additional fields or use the Find Levels 
button as desired. 
Name 
Purpose 
TRLP-Dp 
To verify that the 15%-85% Rise Time (TRLP) of the DUT’s Data & Clock Lanes LP transmitter is 
within the conformance limits. 
TRLP-Dn 
TRLP-CLKp 
TRLP-CLKn 
TFLP-Dp 
To verify that the 15%-85% Fall Time (TFLP) of the DUT’s Data & Clock Lanes LP transmitter is 
within the conformance limits. 
TFLP-Dn 
TFLP-CLKp 
TFLP-CLKn 