User manual
Serial Data Debug Solutions 
138 
919586 RevA 
BRIEF LP TIMING TEST DESCRIPTIONS 
  With LP Timing selected in the Category field, the following Measure values are available: 
TLP-PER-Data-500, TLP-PER-Data-930, TLP-PULSE-Data-500, TLP-PULSE-Data-930, FIRST-TLP-PULSE-Data-
500, FIRST-TLP-PULSE-Data-930, LAST-TLP-PULSE-Data-500, and LAST-TLP-PULSE-Data-930. 
Name 
Purpose 
TLP-PER-Data-500 
To verify that the period (TLP-PER-TX) of the DUT’s Data Lane LP transmitter 
XOR Clock is within the conformance limits. 
TLP-PER-Data-930 
TLP-PULSE-Data-500 
To verify that the pulse width (TLP-PULSE-TX) of the DUT’s Data Lane LP 
transmitter XOR Clock is within the conformance limits. 
TLP-PULSE-Data-930 
FIRST-TLP-PULSE-Data-500 
FIRST-TLP-PULSE-Data-930 
LAST-TLP-PULSE-Data-500 
LAST-TLP-PULSE-Data-930 
BRIEF LP SLEW RATE TEST DESCRIPTIONS 
  With LP Slew Rate selected in the Category field, the following Measure values are available: 
SR-MAX-Dp, SR-MAX-Dn, SR-MAX-CLKp, SR-MAX-CLKn, SR-FALL-MIN-Dp, SR-FALL-MIN-Dn, SR-FALL-
MIN-CLKp, SR-FALL-MIN-CLKn, SR-RISE-400-700-MIN-Dp, SR-RISE-400-700-MIN-Dn, SR-RISE-400-700-
MIN-CLKp, SR-RISE-400-700-MIN-CLKn, SR-RISE-700-930-MIN-Dp, SR-RISE-700-930-MIN-Dn, SR-RISE-
700-930-MIN-CLKp, and SSR-RISE-700-930-MIN-CLKn. 
Name 
Purpose 
SR-MAX-Dp 
To verify that the Slew Rate (δV/δtSR) of the DUT’s Data & Clock Lanes LP 
transmitter is within the conformance limits, for specific capacitive loading 
conditions. 
SR-MAX-Dn 
SR-MAX-CLKp 
SR-MAX-CLKn 
SR-FALL-MIN-Dp 
SR-FALL-MIN-Dn 
SR-FALL-MIN-CLKp 
SR-FALL-MIN-CLKn 
SR-RISE-400-700-MIN-Dp 
SR-RISE-400-700-MIN-Dn 
SR-RISE-400-700-MIN-CLKp 
SR-RISE-400-700-MIN-CLKn 
SR-RISE-700-930-MIN-Dp 
SR-RISE-700-930-MIN-Dn 