Trigger Capability 
CANbus TD and TDM 
# Data Bytes = 0 to 8. Data can be defined by nibble. Triggers on that 
data pattern regardless of position. 
Binary: 
Any combination of 0,1, or X for 1-64 bits. Triggers on that data pattern 
regardless of position. 
Bit Rates 
10, 25, 33.333, 50, 83.333, 100, 125, 250, 500, 1000 kb/s or user-defined 
between 10-1000 kb/s. 
Trigger Input 
Any analog Channel or the EXT input. 
Trigger Design 
Internal to oscilloscope, settable like any other oscilloscope trigger. 
Search Capability 
CANbus TD and TDM 
Search Options 
Search for Any Frame, Any Error or Frame ID in Hexadecimal format. 
Measure and Graph 
Capability 
CANbus TD 
CANbus TDM 
CAN Timing 
Measurements 
Not Applicable 
CAN-CAN, CAN-Analog, Time@CAN, 
CAN Message Bitrate. 
CAN Data Extraction 
Not Applicable 
CAN-Value. 
CAN Bus Load 
Measurements 
Not Applicable 
CAN Bus Load %. 
Graphing Functions 
Not Applicable 
Track, Trend and Histogram of CAN 