User manual
l Timestamping can be turned on and off while data is being captured. As a result, the capture buffer may have
some data with a timestamp, and some data without. When doing a search by timestamp, the analyzer ignores
all data without a timestamp.
l The raw timestamp value is the number of 100-nanosecond intervals since the beginning of January 1, 1601.
This is standard Windows time.
5.1.4 Using Go To
Searching with Go To allows you to go to a particular frame or event, or to move through the data X number of
events or frames at a time. You can move either forward or backwards through the data.
To access the Go To function:
1. Open a capture fileto search.
2.
Open the Event Display or Frame Display window.
3.
Click on the Find icon or choose Find from the Edit menu.
4. Click on the Go To tab of the Find dialog.
5. The system displays the Find dialog with the Go To tab selected.
Note: The tabs displayed on the Find dialog depend on the product you are running and the
content of the capture file you are viewing.
Figure 5.7 - Find Go To tab
To go to a particular frame :
1. Select the Frame Number radio button
2. Type the frame number in the box.
3. Click the Go To button.
TELEDYNE LECROY Chapter 5 Navigating and Searching the Data
166 Frontline BPA low energy Hardware & Software User Manual