User manual
Operator’s Manual
922244-00 Rev A
87
B
Modulation Segment Editor
Click the Add Segment button to open the Edit Modulation Segment
screen.
This screen allows you to edit a Segment - a time interval (Duration) in
which the samples of the modulation signal follow a predefined function
(Type).
The selectable functions and their available parameters include:
Type
Parameters
Sine
Cycles, Amplitude*, Phase (°), Offset*
Cosine
Cycles, Amplitude*, Phase (°), Offset*
Triangle
Cycles, Amplitude*, Phase (°), Offset*
Rectangle
Cycles, Amplitude*, Phase (°), Offset*,
Duty Cycle (%)
Sawtooth
Cycles, Amplitude*, Phase (°), Offset*
Increase Ramp
Amplitude*, Offset*
Decrease Ramp
Amplitude*, Offset*
Table 3-1.Asterisk * indicates the parameter varies based on the modulation type
selected.