5.8.2 TR069
TR-069 is a standard for communication between CPEs and the auto-configuration server (ACS). If your
service provider uses the TR069 automatic service provision function, the ACS automatically provides
the CPE parameters. If you set the ACS parameters on both the CPE and ACS, the network parameters
on the CPE are automatically set using the TR-069 function, and you do not need to set other
parameters on the CPE.
To configure the CPE to implement the TR-069 function, perform the following steps:
1. Choose System>TR069.
2. Set acs URL source. There are two methods, such as URL and DHCP.
3. In the ACS URL box, enter the ACS URL address.
4. Enter ACS user name and password for the CPE authentication.
To use the CPE to access the ACS, you must provide a user name and password for
authentication. The user name and the password must be the same as those defined on the ACS.
5. If you set Periodic inform to Enable, set Periodic inform interval.
6. Set connection request user name and password.
7. Click Submit. As shown in Figure 5-52.
Figure 5-52