User manual

Description for Kabel Light@Night:
If you use the PC-light control Light@Night and you do not want to connect the Light-Display respectively Light-Power Module directly
onto each other but prefer the installation of the module at a larger distance you can use the Kabel Light@Night with a length of 2
meters.
Insert the pin-plug connector of the connection cable with the pin plug into the 10-poles socket bar of the previous Light-Display
respectively Light-Power Module at a position that the white single wire of the connection cable corresponds to the white marking at the
Light-Display respectively Light-Power Module.
The other side of the cable has to be connected to the 10-poles pin-plug of the next module. Also on this side it has to be assured that
the white single wire of the connection cable corresponds to the white marking at the Light-Display respectively Light-Power Module.
The following draft shows the correct connection of the connection cable. The cable has to show to the top.
white
weiss
white
weiss
KL4 KL3 KL2 KL1
KL7
BU1
ST1
4
5
6
7
8
26
27
28
29
30
31
32
25
9
10
11
12
13
14
15
16
18
19
20
21
22
23
24
17
1
2
3
GBS-Display / Light-Display
Rev. 1.7
Littfinski DatenTechnik (LDT)
KL5
braun
gelb
10...18V~
12...24V=
KL6
BU2
IN
39
38
37
36
35
34
33
40
BU3
OUT
weiss
white
xm
weiss
white
Stiftleiste (Adapter)
pin plug (adapter)
Bestellbezeichnung /
Order code: Kabel Light@Night xm
Light Interface (LPT)
Rev. 1.0
Littfinski DatenTechnik (LDT)
BU1
IC2
IC3
IC4
BU2
IC1
C2
C1
Printer
Port
LPT
white
weiss
white
weiss
KL4 KL3 KL2 KL1
KL7
BU1
ST1
4
5
6
7
8
26
27
28
29
30
31
32
25
9
10
11
12
13
14
15
16
18
19
20
21
22
23
24
17
1
2
3
GBS-Display / Light-Display
Rev. 1.7
Littfinski DatenTechnik (LDT)
KL5
braun
gelb
10...18V~
12...24V=
KL6
BU2
IN
39
38
37
36
35
34
33
40
BU3
OUT
Please pay attention: The first Light-Display respectively Light-Power Module has always to be connected directly to the Light-
Interface. Therefore is it only possible to use the connection cable Kabel Light@Night for the connection of the second to the first
Module.
Further products from the Digital-Professional-Series:
Kabel s88 0,5m / Kabel Light@Night 0,5m
Connection cable (0,5m) for the s88-feedback bus and the PC-Light Control Light@Night.
Kabel s88 1m / Kabel Light@Night 1m
Connection cable (1m) for the s88-feedback bus and the PC-Light Control Light@Night.
S-DEC-4
4-fold turnout decoder for four magnet accessories with free programmable decoder addresses and possible external power supply.
SA-DEC-4
4-fold switch-decoder with four bistable relays and free programmable decoder addresses and possible external power supply.
LS-DEC-DB, -DR, -KS, -ÖBB, -SBB, -NS, -NMBS, -BR, -FS, -SJ, -SNCF
4-fold light signal decoder. Light signals switched directly via decoder addresses.
RM-88-N / RM-88-N-O
16-fold feedback modules for the s88-feedback bus. RM-88-N-O with integrated opto coupling.
RM-BG-8-N
8-fold feedback modules with integrated track occupancy detectors for the s88-feedback bus.
HSI-88-(USB)
High Speed Interface for the s88-feedback bus. Offers the possibility to create three feedback lines. The feedback reports will be
transmitted directly via the command station via the COM- (HSI-88) or the USB-Interface (HSI-88-USB) to the PC.
Made in Europe by
Littfinski DatenTechnik (LDT)
Kleiner Ring 9
D-25492 Heist/Germany
Phone: 0049 4122 / 977 381
Fax: 0049 4122 / 977 382
Internet: http://www.ldt-infocenter.com
Subject to technical changes and errors. 02/2015 by LDT
Märklin and Viessmann are registered trademarks