11.3. Output function: properties push button/switch
If you want to activate or deactivate manually the output functions, which are
connected via one of the 8 push buttons or switches to a Basic-Module you have
to depress the key ABOVE or BELOW until the display indicates >Button/Switch<.
Depress now the key RIGHT.
If there was no external key determinates for the
output function will be the display indicate “-“.
If there was already a key determinates this will be indicated at the display.
Activate now the button or switch-on and -off the switch which shall activate and
deactivate the output function. The display shows now the number of the button or
switch.
If you activate this button later during the day phase the output-function will be
activated respectively deactivated by activating the button again.
If you use a switch for this function there will be the output-function activated as
soon as you switch-on the switch. If you switch-off the output-function will be
deactivated.
11.4. Output function: properties DCC-address
If you want to activate and deactivate the output function digital via a DCC-
Address you have to depress the key ABOVE or BELOW until the display indicates
>DCC-Address<. Depress now the key RIGHT.
If there was so far no DCC-Address programmed
for the output function this will be indicated at the
display with “----“.
If there was already a DCC-Address programmed this will be indicated at the
display. Send now a DCC-Address from your digital central unit or your model
railway control software, which shall activate or deactivate the output-function.
It has to be an accessory-address such as used for the switching of turnouts. If the
Light-DEC will recognize the DCC-Address this address will be indicated at the
display.
Receives the Light-DEC later at the day-phase the programmed DCC-Address with
the additional information of turnout straight the output-function will be activated.
If the programmed DCC-Address with additional information of turnout round will
be received the Light-DEC will deactivate the output-function.
Generally applies: If output-functions will be deactivated via the switching time of a
switch-group or button/switch the actual running cycle of a light function will be at
first processed. Only then will be the light function actually switched off. This
follows that with reference to the complexity of the light function the deactivation
will be timely delayed by several seconds. By deactivation via a DCC-Address will
be the output function immediately switched off without waiting for the end of the
actual processed light-cycle.
Property
DCC
-
Address:
----
Property
Ext. Button:
-