1.3. Performance Parameter
Parameters
Unit
Minimum
Typical
Maximu
m
Remarks
Range
mm
30
-
300
70% target reflectivity
Scan
Frequency
Hz
-
28
-
Adaptive adjustment
according to ambient light
conditions
Ranging
Accuracy
%
-
±3.5
-
Within 100mm
%
-
±4
-
From 100mm to 300mm
Viewing Angle
°
-
90
-
Measured at 120mm
Angular Error
°
-
-
2
Angular
Resolution
°
-
0.5
-
Anti-ambient
Light
KLux
-
-
25
Life Time
h
10000
-
-
2. Data Interface
2.1. Communication and Interface
LD07 uses the ZH1.5T-4P 1.5mm connectors to connect with the external system to
implement power supply and data receiving. The specific interface definition and parameter
requirements are as following:
No
Signal
Type
Description
Minimu
m
Typical
Maximu
m
1
TX
Output
UART TX
0V
2.8V
3.63V
2
RX
Input
UART RX
0V
2.8V
3.63V
3
VCC
Power
Power
3.1V
3.3V
3.63V
4
GND
Power
GND
-