Specifications
Table Of Contents
Document is the property of LDL-Technology and cannot be
reproduced or transmitted without written consent
WUS MOTO Gen3 HD
Mounting process
Ref : C 317 109 0000
Version : A1
4.1. SPECIFICATIONS
Screwing torque for valve core mechanism: 0.3 +/- 0.1 Nm.
Screwing torque for valve cap: 0.2 to 0.35 Nm.
Manual screwing torque for T15 Screw: 2,1Nm +/- 0.1 Nm.
Operating Relative Pressure Range: 0 to 3,5 bars.
Relative Maximum pressure range non destructive: 0 to 10 bars
Compatible Inflating Fluid: Air or Nitrogen
Anti-puncture Fluid utilisation: Utilisation without any consequence.
Just introduce Fluid when the valve
is down, close to the ground
Maximum speed of the vehicle: 250 Km/h on rim 17”
********************************************************************************************************************
NOTA :
5. WUS MOUNTING
5.1. PRECAUTIONS DURING MOUNTING OPERATION
¨ Do NOT use WUS after a drop of more than 1 meter on a hard ground
¨ Do NOT generate an electrostatic discharge higher than 6 Kilovolts by air onto the WUS, during
mounting and disassembly of the WUS or at any time during utilization (avoid the use of nylon
worksuit, and in general way, avoid all textile rubbing before handling WUS)
¨ Do NOT store WUS at temperatures higher than 30°C and lower than 0°C
¨ When removing the core from the valve, it has to be replaced by a new chromed short core
(brass without chrome is forbidden) of the same type, according to V0.07.1 ETRTO core
chamber specification.
C317-109-0000-A1-WUS Gen3 HD Mounting Specification.odt LDL Technology SAS
6/ 19 France
Copyrights 2019