Specification Sheet
LCN CLOSERS
121 W
. RAILROAD A
VE.
P.O. BOX 100
PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400
F
AX 800-248-1460
www.lcn.ingersollrand.com
9/07
19
STOP FACE (PUSH SIDE)
MOUNTING
Information applies to 4040 SE closers
unless otherwise specified.
MAXIMUM OPENING
Templating allows 110°.
Hold-open points between 85° and
110° in approximately 3° increments.
SEL track provides hold-open points
between 90° and 120°‚ in
approximately 3° increments.
SE, SEL ELECTRICAL OPTIONS
These track assemblies require a
single power circuit for the holding
solenoid.
SE or SEL holding solenoid is either
24V or 120V input, please specify.
An optional 4040SE-3210
TRANSFORMER reduces 120V AC line
voltage to 24V AC.
Circuitry accepts either AC or DC input.
Butt Hinges should not exceed 5" (127 mm) in width.
Auxiliary Stop is recommended at hold-open point.
Top Rail minimum 5 3/4" (146 mm).
Installation with PLATE, 4040SE-18PA requires SPECIAL TEMPLATE and
2" (51 mm) minimum top rail.
Stop Width 1 1/4" (32 mm) minimum.
Door Width 2'4" (711 mm) minimum for single door with SE.
4'8" (1422 mm) minimum for paired doors with SE.
Wiring Diagram
Options
Long (SEL) track.
Metal or lead lined cover.
24V or 120V input for SE or
SEL, please specify.
Special Templates
Customized installation
templates or products may be
available to solve unusual
applications. Contact LCN for
assistance
.
LCN 4040SE SERIES
SE WIRING DIAGRAM