Application Guide
Table Of Contents
-
7
-
addition.
14. NCV sonsor
Can sense the strong electric field, lights the NCV indicator LED.
5. SPECIFICATIONS
Accuracy is guarantied for 1 year 23°C±5°C less than 80%RH
5-1. DC VOLTAGE (Auto ranging)
Range
Resolution
Accuracy
600mV
0.1mV
±(0.8% of rdg + 5dgts)
6V
1mV
±(0.8% of rdg + 3dgts)
60V
10mV
600V
100mV
±(1.0% of rdg + 5dgts)
Input Impedance: 10MΩ
Overload Protection: 600V DC/AC rms
Max. Input voltage: 600V DC
5-2. AC CURRENT (Auto ranging)
Measuring voltage drop: 200mV
Frequency Range: 40 to 200Hz
5-3. AC VOLTAGE (Auto ranging)
Range
Resolution
Accuracy
600mV
0.1mV
±(1.2% of rdg + 8dgts)
6V
1mV
±(1.0% of rdg + 8dgts)
60V
10mV
600V
100mV
±(1.2% of rdg + 8dgts)
Input Impedance: 10MΩ
Frequency Range: 40Hz ~ 400Hz
Overload Protection: 600V DC/AC rms
Response: Average, calibrated in rms of sine wave
Max. Input voltage: 600V AC rms
Overload Protection: 250V DC/AC rms
Range
Resolution
Accuracy
2-20A
100mA
±(3.0% of rdg + 5dgts)
200-600A
1A