Instructions / Assembly

15
SAFETY CHECK
i. Hose checking step:
(1) Unscrew 2pcs M8 x 55 bolts, 2pcs M8 x 85
bolts and 4pcs M8 cap nuts from transom
control assembly and transom mounting
plate.
(2) Pull out the transom control assembly,
e.lop eht mor f rotaluger & esoh
(3) Check if there are cracks or worn
sections on the hose. If yes, replace the
hose & regulator immediately.
(4) Check for leaks according to the above
step by step after replacing the
hose & regulator.
WARNING: ONLY AN AUTHORIZED GAS TECHNICIAN SHOULD INSTALL THIS PRODUCT.
e. If no bubbles appear, the connection is safe.
battery compartment cover
4pcs M4 x 10 bolts.
inlet pipe fitting and metal
hose fitting.
f. If bubbles appear, there is a leak. Shut off
the LP gas cylinder valve, loosen and then
re-tighten this connection.
line. Do not attempt to use the heater.
Inlet pipe fitting
Metal hose fitting
Battery compartment cover
M4 x 10 bolts 4pcs