WARNING: DO NOT attempt to operate heater until you have
read and understood all precautions.
Failure to do so can result in serious personal injury, death and/or
property damage.
Before turning gas supply ON
Your heater was designed and approved for OUTDOOR USE ONLY .
Do Not use it inside a building ,or any other enclosed area.
Make sure surrounding areas are free of combustible materials, gasoline
And other flammable vapors or liquids.
Ensure that there is no obstruction to air ventilation.
Be sure all gas connections are tight and there are no leaks.
Be sure that access
panels clear of debris.
Be sure any component removed during assembly or servicing is
replaced and fastened prior to starting.
Before Lighting
Heater should be thoroughly inspected before each use, and by a qualified
service person at least annually.
If relighting a hot heater, always wait at least 5mins.
Our heater is tested for quality assurance.
Ignition attempts should succeed 8 out of 10 attempts.
LIGHTING INSTRUCTIONS
1. Turn the control knob to “OFF” position
2. Open base assembly door
3. Turn gas supply “ON” by connecting propane cylinder to regulator inlet.
Check f
or leaks by applying soap solution to cylinder and regulator connection.
4. Push in gas control knobs lightly and turn counterclockwise to “ON”
t his will light the burner. If needed, keep depressing and turn control knob
counterclockwise until the burner lights.
5.Keep the control knob depressed or at least 30 seconds after lighting burner. After
30 seconds release the control knob.
6.If burner does not stay lit, repeat steps 4 to 5
7.W
hen burner is lit, turn gas control knob counterclockwise to desired higher setting.
8.Close base assembly door.
Note: he flame pattem at the emitter grid should be visually checked wheneverT
heater is operated. Normally the burner flame is blue, but a little yellow flame is
acceptable.
If flames extend beyond the emitter grid or there are black spots that have
accumulated
on the emitter grid or reflector, immediately turn off the patio heater,
the heater should
not be operated again until it has been serviced and repaired
b
y a qualified gas technician.
9
OPERATION
WARNING
FOR YOUR SAFETY
DO NOT touch or move heater for at
least 45 minutes after use.
Allow emitter and dome to cool before
touching.
WARNING
FOR YOU SAFETY:
If at any time you are unable to light
burner and smell gas, wait 5 minutes
to allow gas to dissipate before
attempting to light heater. If after 1
minute, you are unable to light
burner, wait 5 minutes and allow
flammable vapors to dissipate before
attempting to light heater again.