Installation Guide
47 
and magnitude of energy that the lift utilizes and shall understand the 
associated hazards. 
 
ELECTRICAL:
 Located at the user control panel, press the “E-STOP” 
button to disconnect the raise and lower functions. 
ELECTRICAL ENERGY IS STILL PRESENT AT THE LIFTS 
ELECTRICAL PANEL WHEN THE EMERGENCY    STOP 
BUTTON IS PRESSED. ELECTRICAL ENERGY MUST BE 
TURNED OFF AND ISOLATED AT THE DISCONNECT 
PANEL PRIOR TO PERFORMING SERVICE OR 
MAINTANANCE ON THE LIFT. 
ISOLATION AND VERIFICAITON PROCEDURES: 
Table 1: ISOLATION AND VERIFICATION PROCEDURES:     
ENERGY TYPE 
AND SOURCE 
LOCKOUT 
LOCATION 
(TO BE 
COMPLETED 
BY END 
USER) 
PROCEDURE FOR LOCING OUT 
AND OR RELEASING ENERGIES 
VERIFY PROCEDURES 
STORED 
ENERGY 
AND 
HYDRAULIC 
PRESSURE 
3000-5000 
PSI
LOWER THE LIFT TO ITS 
LOWEST REST POSTION. IF THE 
LIFT MUST BE SERVICED OR 
MAINTAINED IN THE RAISED 
POSITION, ENSURE THAT THE 
LIFT IS PLACED ON THE 
MECHANICAL LOCKS. 
FOR SCISSOR LIFTS, 
ADDITIONAL SUPPORT WITH 
SUPPLEMENTARY JACK 
STANDS, BLOCK AT THE 
SLIDERS AND A COME ALONG 
SECURED BETWEEN THE 
SCISSORS. 
FOR 4-POST LIFTS, ADDITIONAL 
SUPPORT WITH 
SUPPLEMENTARY JACK 
STANDS. 
VERIFY THAT THE LIFT IS (IF 
APPLICABLE): 
CONTACTING THE 
MECHANICAL LOCKS, 
RESTING ON THE 
SUPPLEMENTARY JACK 
STANDS, 
BLOCKS ARE SECURLY PLACED 
COME ALONG IS SECURED 
BETWEEN THE SCISSORS. 