SAFETY RELEASE CABLE ROUTING AND ADJUSTMENT 
The mechanical safety automatically engages. To release the mechanical safety, 
you must first raise the lift approximately 2”, and then pull the safety release lever 
down. This disengages the power side safety locks and activates the safety cable to 
release the slave side safety lock. 
Included in the parts packaging you will find the extra-long steel single point lock 
release cable, cable clamps and four (4) metal cable guides and two (2) white nylon 
cable guides with two (2) small retaining rings.   
Using the provided bolts attach one metal cable guide to the inner edge at the top of 
each column. Attach another metal cable guide to the outer inside edge of the 
overhead beam. See the photo below for reference. 
Single Point Lock Release Cable 
Guides mounted to the column 
and to the overhead beam. Mount 
as shown to both columns. For the 
TLT211-AS model a cable guide is 
not used on the overhead beam.