Installation Guide
30 
CONNECTING THE POWER SUPPLY 
1)    A 
certified electrician
 must connect the 230Volt/1Ph power unit and 
the overhead Shutoff Switch to the electrical supply. 
2)    Remove the sealed cover on the electrical junction box on the power 
unit and connect the wiring according to the wiring diagram. See 
Figure 9 
3)    A power supply switch is required to be installed near the lift for 
rapidly disconnecting the electrical power supply during maintenance 
or in case of emergency.   
Figure 9 
Note: Motor damage due to improper wiring is not warranted. Verify if the oil 
tank is full; do not operate if there is no oil. After pressing the up button, if 
the power unit does not run or makes unusual noises or has excessive heat 
stop the power unit immediately and check of proper electrical connections.