User's Manual
LAUNCH
S3001 User Manual
109
2. Connect the B-shaped terminal of the USB cable to the Scopebox USB port,
and the other end to the USB port of the diagnostic tool.
3. P
lug the BNC end of secondary ignition pickup into CH1/CH2/CH3/CH
4
channel of the Scopebox, and connect the high-voltage clip to high-voltage
line, and crocodile clips to ground.
*T
ips: Common ignition sequence (the specific sequence is subject to the actual
engine ignition sequence)
Four-stroke in-line four-cylinder: 1-2-4-3, or 1-3-4-2
Four-stroke in-line six-cylinder: 1-5-3-6-2-4, or 1-4-2-6-3-5
Four-stroke in-line eight-cylinder: 1-8-4-3-6-5-7-2
Five-cylinder: 1-2-4-5-3
V 6 engine: generally speaking, based on the person sitting on the driver cab, if
the right side cylinder numbers on the right side, from the front to the back are as
follows: 1, 3, 5; and the cylinder numbers on the left side, from the front to the
back are as follows: 2, 4, 6; then the ignition sequence is: 1-4-5-2-3-6. If
the cylinder numbers on the right side, from the front to the back are as follows:
2, 4, 6; and cylinder numbers on the left side, from the front to the back are as
follows:1, 3, 5; then the ignition sequence is: 1-6-5-4-3-2.
Figure 13-1 below shows the normal ignition waveform of distributor ignition
system, the upper one is the secondary waveform, and the lower one is the
primary waveform.
The secondary waveform
A section is contact open period; B section is make contact period, which is the
magnetizing field of ignition coil.