User's Manual
Table Of Contents
14.3.2 Barometer Mode - Menu 2, Adjusting Ambient Pressure
Why Ambient Pressure need to be Adjusted
+
+
+
+
For achieve higher accuracy, this Watch includes an adjustment feature which allow user to
adjust the ambient pressure.
Before adjusting the ambient pressure, obtain another referring barometer to get the ambient
pressure of your current position.
During the adjustment, input that ambient pressure into the Watch.
IMPORTANT: Input a incorrect pressure during the adjustment procedure, it results a mistaken
pressure reading in future.
See 14.3\Cur. Pres\ to adjust the Ambient Pressure.
Ambient Pressure Adjustment
300m
600m
900m
altitude
0m
sea level
before the
adjustment
get the mbienta
pressure from
another referring
barometer
after the
adjustment
940
mb
943
mb
943
mb
14.3.1 Barometer Mode - Menu 1, Adjusting Sea Level Pressure
Why Sea Level Pressure need to be Adjusted
+
+
+
+
+
+
This Watch includes a Sea Level Pressure adjustment feature, which CAN:
To achieve a more accurate Sea Level Pressure,
To achieve a more accurate Altitude (In case the exact altitude is NOT available for caibrating
the reference altitude).
Before calibrate the sea level pressure, consult the nearest observatory to get the sea level
pressure of your current position.
During the adjustment, input that Sea Level Pressure into the Watch.
IMPORTANT: Input an incorrect pressure during the adjustment procedure, it results a mistaken
pressure reading in future.
See 14.3\SLP\ to adjust the Sea Level Pressure.
Sea Level Pressure Adjustment
300m
600m
900m
absolute
altitude
0m
sea level
before the
adjustment
get t h e sea
level pressure
from weather
station
after the
adjustment
1013
mb
1016
mb
1016
mb
14.2 Barometer Mode - Setting the Units
Level 2
Level 3
+
Adjustment
+
Adjustment
hold
[M]
Level 1
1 . S L P ( S e a L e v e l
Pressure setting).
2 .Cur. P r e s (Current
Pressure calibration)
3.Vw.Log (View Max.,
Min, and the 48 hour
altitude)
Barometer Mode
14.3 Mode: Barometer Function Menu Barometer
hold [S/S]
Frehenheit
Celsius
Temperature unit
Pressure unit
milibar
inHg
hPa
[L/R]
[L/R]
[L/R]
Temperature Display
+
Mx.Tmp
(Maximum
temperature)
+
Mn.Tmp
(Minimum
temperature)
+
Mx. SLP
(Maximum
Sea Level
Pressure)
+
Mn. SLP
(Minimum
Sea Level
Pressure)
[L/R]
+
Scroll the menu
+
Change the setting
[S/S]
+
Scroll the menu
+
Change the setting
[M]
+
Confirm the
selection/setting
+
Go to next setting
level
[ESC]
+
Exit the current
display
+
Go to last setting
level
NOTE: See 14.3.1 - 14.3.3 for more detail of this function menu.
+ The pressure and temperature display unit can be changed in Barometer Mode or in Current
Time Mode. See 4.2\unit\ for the details of the setting.
+
-1 hour log
( a t t h e
p r e c e d i n g
hour)
+
- 2 ~ - 47
hour logs
+
- 4 8 h o u r
log
[M] [L/R]
[S/S] [ESC]
[EL]
[M] [L/R]
[S/S] [ESC]
[EL]
[M] [L/R]
[S/S] [ESC]
[EL]
[M] [L/R]
[S/S] [ESC]
[EL]