Installation & Assembly
Table Of Contents
Date Issued: 09/11/17
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
1) Pass xture wire through desired amount of stems [1] and
screw stems together using supplied short threaded tubes [2].
NOTE: Thread locking compound must be applied to all stem
threads as noted with arrow symbol to prevent accidental rota-
tion of xture during cleaning, relamping, etc.
2) Pass xture wire through end of swivel [3] without threaded
pipe.Thread that end of swivel onto end of last stem.
NOTE: Direction of swivel in accordance with ceiling.
3) Pass xture wire through hole in canopy[4]. Pass threaded
pipe on end of swivel up through hole in canopy.
4) Pass xture wire through lockwasher [5] . Thread lockwasher
onto end of threaded pipe protruding from inside canopy.
5) Pass xture wire through hexnut [6]. Thread hexnut onto end
of threaded pipe.
6) Find the appropriate threaded holes on mounting strap [7]. As-
semble mounting screws [8] into threaded holes.
7) Attach mounting strap to outlet box [9]. Mounting strap can be
adjusted to suit position of xture.
8) Grounding instructions: (See Illus. A or B).
A) On xtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On xtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If xture is provided with ground wire. Connect xture ground
wire to outlet box ground wire with wire connector. (Not pro-
vided.) After following the above steps. Never connect ground
wire to black or white power supply wires.
9) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.
10) Push xture to ceiling, carefully passing mounting screws
through holes in canopy. NOTE: Be certain wires do not get
pinched between canopy and ceiling.
11) Use lock-up knobs [10] and lockwashers [11] to secure
canopy. Tighten to secure.
12) Ensure that the threaded stud strain relief [12] is tightened.
13) Carefully raise glass [13] to the xture. Slip the smaller
opening over the socket [14] and press the glass against the
socket.
14) Thread socket ring [15] onto socket. Tighten socket ring to
secure glass in place. (DO NOT over tighten.)
15) Insert recommended bulb. (Not supplied)
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso)
*Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
8
7
6
5
4
10
11
3
13
►
►
►
1
2
►
12
14
15
9