Installation & Assembly

CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
1) Pass xture wire from coupling[1] on top of xture through end
of stem[2]. (Be sure the stem has a short threaded tube[3] on
each end.) Thread the stem into the coupling.
2) Pass top of stem through hole in canopy[4].
3) Pass xture wire through a lockwasher[5] followed by a
hexnut[6]. Slip the lockwasher onto threaded pipe protruding
from inside canopy. Thread hexnut onto end of threaded pipe.
Tighten to secure.
4) Find the appropriate threaded holes on mounting strap[7]. As-
semble mounting screws[8] into threaded holes.
5) Attach mounting strap to outlet box[9]. Mounting strap can be
adjusted to suit position of xture.
6) Grounding instructions: (See Illus. A or B).
A) On xtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On xtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If xture is provided with ground wire. Connect xture ground
wire to outlet box ground wire with wire connector. (Not pro-
vided.) After following the above steps. Never connect ground
wire to black or white power supply wires.
7) Make wire connections. Reference chart below for correct con-
nections and wire accordingly.
8) Push xture to ceiling, carefully passing mounting screws
through holes in canopy. NOTE: Be certain wires do not get
pinched between canopy and ceiling.
9) Use lock-up knobs[10] and lockwashers[11] to secure canopy.
Tighten to secure.
10) Insert recommended bulb(s) (not supplied).
11) Thread the short end of the threaded pipe[12] into the cou-
pler[13].
12) Thread a hexnut[6] on the bottom threads of the pipe. (Leave
about 3/4” threads exposed ).
13) Slip a steel washer[15] followed by a rubber washer[16] onto
the threaded pipe.
14) Carefully rest the shade[17] onto the glass. Raise up to the x-
ture and slip the hole of the glass[18] over the threaded pipe.
Rest the glass against the rubber washer.
15) Slip a rubber washer followed by a steel washer onto the
threaded pipe.
16) Thread a hexnut[19] onto the threaded pipe to secure the
glass. Do not over-tighten.
17) Thread the nial[20] onto the threaded pipe to cover the hex-
nut. Do not over-tighten.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
8
7
9
10
11
13
12
15
16
16
15
19
20
17
18
5
6
3
2
1
4
6

Summary of content (2 pages)