SDS

Dalton Enterprises, Inc. Product: Latex•ite® THERMA SEAL Driveway Filler Sealer
Phone: (203) 272-3221 SDS Date: 07/21/2016
Page 3 of 7 Latexite THERMA SEAL
Ingestion: If swallowed do NOT induce vomiting. Seek medical attention if symptoms develop.
Inhalation: Move to fresh air if symptoms develop. If irritation persists see a physician.
Most Important Symptoms: Possibility of minor eye and skin irritation.
Indication of Immediate Medical Attention and Special Treatment Needed: Treat Symptomatically
Section V FIRE-FIGHTING MEASURES
Suitable Extinguishing Media: Water, CO2, dry chemical, foam, sand.
Unsuitable Extinguishing Media: N/A
Specific Hazards arising From the Chemical: Combustion may yield fumes, smoke, carbon monoxide and
carbon dioxide.
Special Protective Equipment and Precautions for Firefighters: Wear full protective clothing, including
self-contained breathing apparatus (Positive Pressure/Pressure Demand), helmet, and face mask.
Section VI ACCIDENTAL RELEASE MEASURES
Personal Precautions, Protective Equipment and Emergency Procedures: Avoid skin and eye contact,
use proper protective equipment recommended in section 8.
Methods and Materials for Containment and Cleanup: Contain spill and dike with inert material (sand,
saw dust, dirt, etc.). Place in closed container for proper disposal. Avoid runoff to waterways and sewers.
Dispose of in accordance with local regulations.
Section VII HANDLING AND STORAGE
Precautions for Safe Handling: Store in a dry area, avoid eye contact and wash thoroughly after handling
Conditions for Safe Storage, Including Incompatibilities: Keep container closed and upright to prevent
leakage. Store in a cool, dry, ventilated area. Avoid freezing. Keep container upright to prevent leakage.
Section VIII EXPOSURE CONTROLS / PERSONAL PROTECTION
Exposure Guidelines
Component
OSHA PEL (TWA) (mg/m3)
Petroleum Asphalt
-
Crystalline Silica
(30)/(%SiO2 + 2) mg/m3 TWA, total dust
(250)/(%SiO2 + 5) mppcf TWA, respirable fraction
(10)/(%SiO2 + 2) mg/m3 TWA, respirable fraction
Engineering Controls: Ensure adequate ventilation
Individual Protection Measures
Eyes/Face: Safety goggles
Skin: Gloves
Respiratory: None required if good ventilation is maintained. This product is an emulsified,
encapsulated mixture which greatly reduces the likelihood of exposure to hazardous particles.