Installation Guide
Wiring
Standard
Reader
Connections
Ethernet
Connections
Voltage dierence between GND and COM_GND should not exceed 25V
Wire Color
GREEN
1
WHITE
2
GRAY
3
YELLOW
4
BLUE
5
ORANGE
6
PURPLE
7
BROWN
8
RED
9
BLACK10
Name Description
A/D0
B/D1
COM_GND
NO/NC
COM
IO1
IO2
IO3
VIN
GND
RS-485 A, Wiegand DATA0
RS-485 B, Wiegand DATA1
Return for A/D0, B/D1 wires
Relay contact
Relay contact
Input/Output
Input/Output
Input/Output
12VDC to 24VDC power input
Return for power input
Rating
0.025A max drive, 5VDC
0.025A max drive, 5VDC
1.5A max, 24V DC
1.5A max, 24V DC
0.35A max sink, 24VDC max
0.35A max sink, 24VDC max
0.35A max sink, 24VDC max
0.5A /12VDC or 0.25A /24VDC
Reference
COM_GND
COM_GND
GND
GND
GND
GND
GND
GND
Wire Color
GREEN/WHITE
11
GREEN
12
ORANGE/WHITE
13
BLUE
14
BLUE/WHITE
15
ORANGE
16
BROWN/WHITE
17
BROWN
18
Name
TX+
TX-
RX+
SPR1
SPR2
RX-
SPR3
SPR4