Manual: ShowNET

Manual: MicroNet Slim - Network Interface
page 8 / 24
DMX settings
3 0-192 Size of the laser projection X axis
193-255 Automatic size change of X axis with increasing speed
4 0-192 Size of the laser projection Y axis
193-255 Automatic size change of Y axis with increasing speed
5 0-192 Position of the laser projection X axis
193-255 Automatic position change of X axis with increasing speed
6 0-192 Position of the laser projection Y axis
193-255 Automatic position change of Y axis with increasing speed
7 0-192 Rotation of the laser projection
193-255 Automatic rotation with increasing speed
8 0-192 Blanking: selects how much of the laser pattern shall be blanked
193-255 Automatic blanking with increasing speed
9 0-192 Blankshift: selects which part of the laser projection shall be blanked (use only
in combination with channel 7 - blanking)
193-255 Automatic blankshift with increasing speed
10 0-15 Show pattern in original colors
16-31 Pattern completely red
32-47 Pattern completely green
48-63 Pattern completely blue
64-79 Pattern completely yellow
channel range function
10 80-95 Pattern completely magenta
96-111 Pattern completely cyan
112-127 Pattern completely white
128-255 Rainbow eect
11 0-31 Default scan speed (200 points per second)
32-255 Manual selection of scanspeed (5000 - 30000 points per second)
Attention: make sure not to overload the scanners of the laser projector! If
you‘re unsure about the maximum scanspeed of your laser projector, stay with
the default setting.