User Manual
Laserworld Showeditor 2015
Version 2015/1.0 2015 Page 24
Fig. 10: Tab Optimize Output. Setting of hardware interface parameters
If scan speed settings of more than 25’000pps are selected, a warning message
shows up, explaining that this may damage scanners if not used with precaution. You
can stop this dialog box from opening up again by clicking “No” (“Nein”):
After having set the scan speed, different adaption to the general scanner
behaviour can be made. It is suggested to project a test pattern while adjusting
these fine tuning settings:
INFOBOX:
It is strongly recommended to not daisy-chain an ILDA signal line to connect
laser systems with different scanner systems. Either the slower scanner system is
overdriven when optimizing settings to the faster one, or the faster one can only
run at the speed of the slower one when settings are optimized for this.
Use two different hardware interfaces instead and set the scanner settings per
interface.