User Manual
20
GB
Subject to technical alterations. 07.2010.
Technical data
Function Range Precision
AC current (50/60 Hz) True RMS 200.0 AAC ± (2.5% ± 8 digits)
DC current 200.0 ADC ± (2.0% ± 5 digits)
DC voltage 600.0 VDC ± (1.0% ± 2 digits)
AC voltage (50/60 Hz) True RMS 600.0 VAC ± (1.5% ± 8 digits)
Resistance 999.9 Ć ± (1.5% ± 8 digits)
Function Max. input
A AC / VDC 200A (PEAK 282, 8A)
V DC, V AC 600V DC/AC
Resistance, continuity test 600V DC/AC
Clamp opening approx. 17 mm
Capacitance measurement
Response threshold <30 Ć,
Test current <0.5 mA
Measurement range
10 measurements/sec. for numme-
ric display & 40 measurements/sec.
for bar graph display (DCA, DCV,
resistance measuring)
Input resistance 1.0 MĆ (VDC, VAC)
Frequency range
AC current/voltage
50/400 Hz (True RMS)
PEAK hold measures peak current <10 ms
MAX/MIN hold Measurement range <500 ms
Operating temperature -10°C … 50°C
Storage temperature -30°C … 60°C
Humidity
non-condensing
90% (0°C … 30°C);
75% (30°C … 40°C);
45% (40°C … 50°C)
relative humidity
Height above mean sea level
Operation: 3,000 m;
Storage: 10,000 m
Overvoltage category CAT III - 600V
Power supply 2x 1.5 Type AAA, LR03, alkaline
Dimensions 164 x 65 x 32 mm
Weight 175 g
Test standards
EN 61326; EN 61010-1;
EN 61010-2-031
Manual_MultiClamp-Meter_Rev.0710_GB.indd 20 12.08.2010 16:10:31 Uhr