In order to preserve the batteries, the device switches off
automatically if left idle for 10 minutes. A signal sounds
in advance.
AUTO OFF function
Insertion of batteries
AC current measurements
PEAK hold function
1
2
3
1.
2.
1. Turn the rotary switch to position „200A AC“.
2. Place the current clamp around a line.
3. The measured value is shown on the LC display. .
1.
1. 2.
1. Turn the rotary switch to position „200A AC“ and press the
„MAX/MIN“ button, to activate the PEAK function.
2. Place the current clamp around a line.
3. Switch on the consumer unit you want to measure. The
signiÖ cant maximum value (10 ~ 282.8 A) is displayed.
The measuring device can detect fast current peaks
(<10 milliseconds).