Safety instructions
Make sure that you always select the correct connections, the correct
rotary switch position and the correct range for the measurement to
be taken.
Before measuring or checking the resistance, continuity, diodes or
capacitance, disconnect the power supply to the electric circuit.
Check that all high-voltage capacitors are discharged.
Isolate the device from all current sources before opening the battery
compartment cover.
If possible, do not work alone.
If you have to take hold of the measuring spikes, do so by the grip
sections only. Do not touch the measuring contacts whilst the
measurement is being taken.
If the device comes into contact with moisture or other conductive
residue, work must not be carried out under voltage. At and above
voltages of 25 V AC/60 V DC, the presence of moisture creates
the risk of life-threatening electric shocks. Clean and dry the device
before use. When using the device outdoors, make sure that the
weather conditions are appropriate and/or that suitable protection
measures are taken.
If you are working with voltages higher than 25 V AC/60 V DC,
exercise extreme caution. Touching the electrical conductors at
such voltages poses a risk of life-threatening electric shocks.
Do not use the device in environments in which there are con-
ductive particles or where the occurrence of moisture (in the form
of condensation, for example) can create transient conductivity.
The device must only be used in accordance with its intended
purpose and within the scope of the speciÖ cations.
If you are taking measurements in the hazardous vicinity of
electrical installations, do not work alone and seek guidance
from an electrically skilled person before starting work.
Before taking any measurements, make sure that both the area to
be tested (e.g. a line), the test device and the accessories used (e.g.
connection cable) are in proper working order. Test the device by
connecting it to known voltage sources (e.g. a 230 V socket in the
case of AC testing or a car battery in the case of DC testing). Stop
using the device if one or a number of its functions fails.