Instruction Manual

LaserRange-Master T7
17
Important notices
The laser points to the location that will be measured.
No objects may get into the laser‘s line of measurement.
The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
The measurement results of outdoor measurements may be inuenced
or falsied by rain, fog and snow.
In unfavourable conditions, e.g. with poorly reecting surfaces,
the maximum deviation may be greater than 3mm.
Carpeting, upholstery or curtains will not reect the laser optimally.
Measure to at surfaces.
Measurements made through glass (window panes) can falsify
measurement results.
An energy-saving function switches the device off automatically.
Clean with a soft cloth. Water may not be allowed to penetrate
the housing.
* measuring distance up to 10 m with strongly reflective target surface
and at room temperature. The measurement deviation may increase by
± 0.2 mm/m for greater distances and under unfavourable measuring
conditions such as strong sunlight or weakly reflective target surfaces.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=lrmt7
Technical Data (Subject to technical changes without notice. 17W51)
Inside measurement range 0,2 m - 70 m
Precision (typical)* ± 0,2 mm / m
Laser class 2 < 1 mW
Laser wavelength 635 nm
Power supply 3 x AAA 1.5 Volt batteries
Dimensions (W x H x D) 49 x 115 x 26 mm
Weight (incl. batteries) 145 g
Automatic switch-off 30 sec laser / 3 min device
Operating conditions
-10°C…40°C, Max. humidity
20…85% rH, no condensation,
Max. working altitude 2000 m
above sea level
Storage conditions
-20°C…70°C,
Max. humidity 80% rH
EN