operation manual
MultiMeter
17
GB
Voltage measurement DC
To measure voltage, set the rotary switch to the " " position with
the corresponding measuring range (200 mV - 300 V).
Then connect the measuring contacts to the object to be tested.
The measured value acquired and the polarity appear on the display.
4
20
300 300
10A
BAT.
9V
BAT.
1.5V
200200
2000
m
200
m
2000
k
200
k
20k
2000
200
200m
20m
2000
μ
black red
Notes on measurement
If the value of the measured variable is not known in advance,
set the rotary switch to the highest measuring range or use the 10A
connection with the 10A measuring range to measure current.
Then reduce the measuring range step by step until a satisfactory
resolution is achieved.
3
Connection of test prods
The black test prod (–) must always be connected to the
"COM socket". When taking current measurements > 200 mA
the red test prod (+) must be connected to the "10 A socket".
For all other measuring functions, the red test prod must be
connected to the "VmAΩ
-socket".
Before measuring, make sure that the test prods are
connected correctly as the built-in fuse could otherwise
trip and damage the measuring circuit.
!
COM VmA 10A
COM VmA 10A
COM VmA 10A
COM VmA 10A
2