operation manual

14
Technical data (Subject to technical alterations. 09/2015)
Self-levelling range ± 2,5°
Precision ± 2 mm / 10 m
Laser wavelength linelaser / plumb laser
635 nm / 650 nm
Laser class / line laser output power 2 / < 1 mW
Laser class / plumb laser output power 2 / < 1 mW
Power supply
3 x 1,5V AA
Operating time approx. 16 h
Operating temperature 0°C ... + 50°C
Storage temperature -10°C ... + 70°C
Weight (incl. batteries) 1,4 kg
Dimensions (W x H x D) 120 x 190 x 120 mm
B
C
2,5 m
< 2 mm = OK
Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m
length on the wall, making sure that the bob can swing freely. Switch on the
device and align the vertical laser to the plumb line. The precision is within
the specified tolerance if the deviation between the laser line and the plumb
line is not greater than ± 1.5 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the
wall. Turn the laser cross approx. 2.5 m to the
right and mark point C. Check whether the
horizontal line from point C is level with point B to within ± 2 mm.
Repeat the process by turning the laser to the left.
Regularly check the adjustment before use, after transport and after
extended periods of storage.
!
GB